Alert Details

VCFRONT_a245_pump1EFuseFault

Description

The front vehicle controller (VCFRONT) detects the pump 1 eFuse for the powertrain (PT) pump and condenser fan is open (tripped), interrupting electrical power supply to the PT pump and condenser fan. HVAC cabin cooling (air conditioning) and powertrain performance will be limited.

Condition

A condition detected by the pump 1 eFuse has caused the powertrain pump and condenser fan eFuse circuit to open (trip).

Clear Condition

The pump 1 eFuse no longer detects a condition causing the PT pump and condenser fan eFuse circuit to open (trip).

Potential Impact

The PT pump and condenser fan will be unavailable. HVAC cabin cooling (air conditioning) and powertrain performance will be limited.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+

Important

No