VCFRONT_a234_autopilot2EFuseFault
Description
The front vehicle controller (VCFRONT) detects the Autopilot 2 eFuse has tripped (circuit opened).
Condition
The Autopilot 2 eFuse high side driver (HSD) detects electrical current flow exceeding normal (expected operating) range, causing the Autopilot 2 eFuse circuit to open (trip).
Clear Condition
VCFRONT detects the Autopilot 2 eFuse is no longer tripped (circuit is closed again).
Potential Impact
Autopilot features are unavailable.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+