Alert Details

VCFRONT_a202_pcsSelfTestFail

Description

The front vehicle controller (VCFRONT) has detected a condition affecting the power conversion system (PCS) low voltage (LV) power feed circuit (eFuse).

Condition

Required voltage conditions are not met during the self-test sequence.

Clear Condition

Vehicle goes through a sleep cycle.

Potential Impact

The low voltage (LV) power feed circuit (eFuse) may be unable to regulate (turn on or off) the power supply to the PCS, which could make vehicle functions relying on the PCS limited or unavailable.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+