MyTeslaMate
VCDOORRL family

VCDOORRL_a121_eFuseManagementContinuous16V

Not Available

What does the VCDOORRL_a121_eFuseManagementContinuous16V alert mean?

Unexpected voltage seen on continuous device outputs

What you'll see in your Tesla

  • Not Available

What triggers it

Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven

When it clears

Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.

Potential impact

Electrical loads for door switch LED, door pocket LED, door puddle LED, and power 15v0 sw fused rail may be unavailable.

Affected models

Cybertruck