SSFA_a159_currentContinuityFault
Description
Steering motor current continuity is irrational. The sum of the three phase currents is not equal to 0.
Condition
Observed current into motor does not match current exiting.
Clear Condition
Current returns to nominal.
Potential Impact
The motor is disqualified and system health is degraded.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Cybertruck