Alert Details

RCU_a006_wakeLineOpen

Description

Redundant Control Unit (RCU) Low Voltage (LV) state CAN signal from Front Vehicle Controller (VCFRONT) reports LV is on while the wake line voltage is off.

Condition

VCFRONT RCU LV state signal VCFRONT_iBoosterLVState is received as LV_ON while the hardwired wake line (RCU connector pin 4) is off for more than 2 minutes while there is no power supply hard undervoltage.

Clear Condition

VCFRONT RCU LV state signal matches hardwired wake line state at the start of the next power cycle.

Potential Impact

The RCU may not power on or shut down correctly.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Model Y 2025+