PCS_a070_chgPfcLineDvdt
Description
The onboard charger input voltage measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected and sudden drop or spike in the measured voltage has occurred, and it is frequently associated with a condition affecting the supply voltage from the AC grid.
Condition
The onboard charger AC input voltage changed too much between switching cycles compared to acceptable range.
Clear Condition
The onboard charger will restart the affected converter(s) automatically until the maximum number of retry attempts has been reached.
Potential Impact
Reduced AC charge rate.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+