Alert Details

PCS_a069_chgPfcLineDidt

Description

The onboard charger AC input current measurement changed too much between switching cycles compared to acceptable range, causing reduced AC charge rate. This alert indicates an unexpected, sudden drop or spike in the measured current has occurred, and it is frequently associated with a condition affecting the supply current from the AC grid.

Condition

The onboard charger AC input current changed too much between switching cycles compared to acceptable range.

Clear Condition

The onboard charger will restart the affected converter automatically until the maximum number of retry attempts has been reached.

Potential Impact

Reduced AC charge rate.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+