PCS2REXB family
PCS2REXB_a014_cycloBTankOverCurrent
Not Available
What does the PCS2REXB_a014_cycloBTankOverCurrent alert mean?
The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold
What you'll see in your Tesla
- Not Available
What triggers it
The DCACB resonant tank current goes above the allowed current threshold
When it clears
The DCAC system retries
Potential impact
DCAC may be limited or unavailable.
Affected models
Cybertruck
Track your Tesla's alerts automatically