Alert Details

PCS2REXA_a114_hvBusEstimatedImpedanceLow

Description

The Power Conversion System (PCS) detects the estimated high voltage (HV) bus impedance is lower than the expected threshold.

Condition

The estimated HV bus impedance is lower than the expected threshold.

Clear Condition

The DCDC converter is commanded to shut down or receives a new request to precharge the HV bus.

Potential Impact

The DCDC converter may not precharge the HV bus to its commanded voltage target, preventing HV battery pack contactors from closing.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Cybertruck