MyTeslaMate
HVP family

HVP_w067_HvilCalNodeMismatch

Not Available

What does the HVP_w067_HvilCalNodeMismatch alert mean?

The High Voltage Interlock Loop (HVIL) type in the High Voltage Processor's (HVP) calibration block or firmware file is mismatched with the expected HVIL node count defined in the numberHVILNodes gateway configuration.

What you'll see in your Tesla

  • Not Available

What triggers it

The HVIL type determined by the HVP is mismatched with the numberHVILNodes gateway configuration.

When it clears

The HVIL type determined by the HVP matches with the numberHVILNodes gateway configuration.

Potential impact

Contactors will open and may remain open while not in the drive state.

Affected models

Model 3 2017-2023 Model 3 2024+ Model S 2021+ Model X 2021+ Model Y Model Y 2025+