HVPACK3_a021_HvSenseAsicFault
Description
The HvSense measurement asic has a SPI communication fault or other internal fault.
Condition
Fault condition was set during SPI communications
Clear Condition
Normal communications restored (after debounce period)
Potential Impact
HvSense readings are stale
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Semitruck