HVLINK family
HVLINK_a033_ShortOnDcLink
Battery system overcurrent error
What does the HVLINK_a033_ShortOnDcLink alert mean?
The HVLINK has diagnosed a short on the DC link.
What you'll see in your Tesla
- Battery system overcurrent error
- PULL OVER SAFELY
What triggers it
The absolute value of slosh current from Bus A to Bus B on the DC Link exceeds 2000A
When it clears
The absolute value of slosh current from Bus A to Bus B on the DC Link falls below 1000A
Potential impact
The FC Pyros are deployed. Fast Charge (FC) link is offline and DC link is split
Affected models
Semitruck
Track your Tesla's alerts automatically
Alerts like this reach MyTeslaMate through your car's Tesla telemetry API. MyTeslaMate logs every alert your Tesla reports and turns it into readable history and real-time notifications — hosted TeslaMate with no server to run.