HVBATT family
HVBATT_a312_InvalidPcsLineConfiguration
AC Charging and Powershare unavailable
What does the HVBATT_a312_InvalidPcsLineConfiguration alert mean?
The High Voltage Battery (HVBATT) electronic control unit (ECU) detects the Power Conversion System (PCS) line configuration is unknown, which may cause AC Charging and Powershare features to be unavailable.
What you'll see in your Tesla
- AC Charging and Powershare unavailable
- Service is required
What triggers it
A valid PCS line configuration is not loaded from the configuration record.
When it clears
The configuration record is programmed with a valid PCS line configuration.
Potential impact
AC charging and Powershare features, such as Home Backup, may be unavailable.
Affected models
Cybertruck