FC_a298_GB_bmsCtrCloseTimeout
Description
The Fast Charge (FC) Electronic Control Unit (ECU) has detected the vehicle pack contactor did not close within the expected 6 second time interval during charging start-up process.
Condition
Vehicle pack contactor does not close within the expected 6 second time frame, resulting in a timeout condition.
Clear Condition
Unplug charge handle.
Potential Impact
Charging session may not start.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+