Alert Details

ESP_a087_BrakeSwitchImplausible3

Description

Brake Pedal Switch Plausibility monitor against master cylinder pressure sensor failed.

Condition

Master cylinder pressure rise is not correlated with switch state

Clear Condition

Check BLS mounting, reporting status, and harness integrity. Run Toolbox Brake Line Switch test, replace BLS if necessary.

Potential Impact

Degrades automatic braking functionality

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+