EPASTP_a207_fdrOclFreezing
Description
This alert is reported by the Output Control Logic (OCL) of the FdrDetectionManager_R12 (FDR) when freezing is detected.
Condition
EPAS application diagnostics detected water freezing temperature problem (torque limit) at vehicler speed higher than limit.
Clear Condition
EPAS power cycle.
Potential Impact
EPAS detected water freezing. EPAS activates retention.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Model Y;Model Y 2025+