EPASTP_a117_mrccStartupRegCsErrorTransientErr
Description
This alert is reported when there is a transient CRC failure in register CRC check.
Condition
EPAS microcontroller's different registers does not contain the right values before starting the safety functions (CRC doesn't match for the first test fail).
Clear Condition
Perform EPAS Software update. Replace HW if the alert persists.
Potential Impact
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Model Y;Model Y 2025+