EPASTP_a093_sctpTsuSingleStaticFail
Description
This alert is reported by the SteeringColumnTorqueProvider_R12 (SCTP) component when 1 TSU sensor fails. Quality of service of the provided torque is other than NOMINAL_FAULT_TOLERANT for at least 400 ms.
Condition
EPAS application steering torque diagnostics detected failure (One TSU sensor).
Clear Condition
Quality of service of the provided torque is NOMINAL_FAULT_TOLERANT.
Potential Impact
One torque sensor failed but EPAS still can operate normal.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Model Y;Model Y 2025+