EPAS3S_a047_motPosCorrError
Description
Difference between motor position sensor 1 and 2 exceeded threshold.
Condition
|MPS1 - MPS2| > 15 degrees
Clear Condition
Calibrate motor position sensor
Potential Impact
Reduced assist and EAC inhibited
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+