DPP1_a042_ecuStateInvalid
Description
CAN messages from the Dual Power Pump (DPP) ECU have an invalid data value, indicating an error in data integrity has been detected.
Condition
5 or more CAN message frames from the DPP ECU have an invalid data value not equal to any of the predetermined states
Clear Condition
System reset, or 3 valid CAN frames are received from the DPP ECU with valid data values
Potential Impact
Steering assist may be affected, since the DPP1 to DPP2 interface is interrupted
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Semitruck