DPP1_a017_motorBlocked
Description
Dual Power Pump (DPP) assist halted due to the motor speed being far below requested.
Condition
1000ms (or 500ms if temperature is more than 80 degrees Celsius) after DPP motor speed request of >500 RPM, the Motor speed is <250 RPM
Clear Condition
System reset
Potential Impact
Steering assist unavailable
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Semitruck