Alert Details

DPP1_a017_motorBlocked

Description

Dual Power Pump (DPP) assist halted due to the motor speed being far below requested.

Condition

1000ms (or 500ms if temperature is more than 80 degrees Celsius) after DPP motor speed request of >500 RPM, the Motor speed is <250 RPM

Clear Condition

System reset

Potential Impact

Steering assist unavailable

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Semitruck