DPP1_a005_inputVoltageHigh
Description
Dual Power Pump (DPP) assist halted due to supply overvoltage.
Condition
DPP drive Stage Voltage > 33V
Clear Condition
Drive stage voltage < 32V for >500ms
Potential Impact
Steering assist unavailable
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service
Models
Semitruck