Alert Details

DPB_a270_RPSVectorRangeLow

Description

rotor position sensor raw signals: vector length is too low.

Condition

Magnetic field too weak or electrical alert of rotor position sensor raw signals.

Clear Condition

Ignition off; wait 5 seconds; Ignition on

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+