DPB_a266_RPSNvMReadFault

Description

Reading of rotor position calibration data from NvM failed.

Condition

Defect NVM or rotor position sensor calibration was not done successfully (new ECU).

Clear Condition

trigger RPS Calibration

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+