Description

At least one command number for safe backbone monitoring not scheduled from system asic watchdog.

Condition

One or more command numbers for safe backbone monitoring and tests are not scheduled by system ASIC. System ASIC defect. All 50 command numbers have to be scheduled by system ASIC during monitoring interval.

Clear Condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+