Alert Details

DPB_a258_valveRelayOffContinuous

Description

VR can not be switched on.

Condition

(1) UVR voltage does not fit to the target VR state, Comparing UVR and UBVR. (2) VR can not be switched on, Comparing UVR and UBVR.

Clear Condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+