Alert Details

DPB_a228_supplyASICInitFault

Description

Initial test/check for ASIC supply parts failed.

Condition

Defect or deviation of ASIC configuration on software and hardware side. Test checks if the voltage regulator configuration of the ASIC matches the software configuration.

Clear Condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+