Alert Details

DPB_a222_excessiveEcuResetsDetected

Description

An excessive number of ECU resets has occurred in a row during actuator initialization (before IPC completion).

Condition

High electric resistance in the IPB power supply. Either due to a weak battery or due to corrosion of the supply cable. The alert is set if several ECU resets in a row have occurred before the initial actuator tests could finish.

Clear Condition

The issue goodchecks itself after some time (either 2 s, 5 s,10 s, or project specific maximum time depending on the number of resets). If it doesn't goodcheck on itself then allow system to complete postrun and power off. Power on again.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+