DPB_a106_ecuBistCmdTestFault
Description
Contrary to spec Built-In Self Test (BIST) state machine of system IC is started by a wrong BIST command.
Condition
Erroneous safety logic (the BIST state machine of the system chip could be activated by a wrong BIST command value), The failsafe logic test tests whether the BIST state machine does detect and suppress a wrong BIST command value. This alert is logged if the watchdog of the system chip is triggered by the wrong BIST command value.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Model Y 2025+