DPB_a103_ecuVrViaSpiFails
Description
The valve relay cannot be switched off via the SPI command of the system IC.
Condition
System chip does not switch off the valve relay gate actuation via SPI or the feedback bit does report a wrong status, The failsafe logic test tests whether the system chip can switch off the gate actuation of the valve relay via SPI command. If the feedback does not show a switched off valve relay gate this fault is set.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Model Y 2025+