Alert Details

DPB_a102_ecuVrOnWhileWdTimeout

Description

The missing watchdog don't switch off the valve relay.

Condition

Erroneous safety logic (Watchdog timeout detection of system chip erroneous). The failsafe logic test tests whether the system chip detects a missing watchdog trigger and therefore swichtes off the gate actuation of the valve relay. If the feedback does not show a switched off valve relay gate this fault is set.

Clear Condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+