Alert Details

DPB_a094_ecuClockTestFault

Description

Clockin monitor of system IC reports wrong clockin alert status to uC.

Condition

Erroneous safety logic (The clockin monitor of the system IC reports wrong clockin alert status to the uC). This alert is logged if the feedback to the uC does not show the expected clockin alert state.

Clear Condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+