DPB_a094_ecuClockTestFault
Description
Clockin monitor of system IC reports wrong clockin alert status to uC.
Condition
Erroneous safety logic (The clockin monitor of the system IC reports wrong clockin alert status to the uC). This alert is logged if the feedback to the uC does not show the expected clockin alert state.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Model Y 2025+