DPB_a093_ecuBistFaultCtrFault
Description
Built-In Self Test (BIST) didn't switch off electrically after too much received wrong BIST commands.
Condition
Erroneous safety logic (BIST of system IC does not switch off electrically after too much received wrong BIST commands), The failsafe logic test tests that after 3 wrong BIST commands the BIST alert counter counted up to its max. value and that the BIST state machine switches off electrically consequently.
Clear Condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Model Y 2025+