Alert Details

DPB_a051_PSCVoltageImplausible

Description

Based on the motor current vector and speed the voltage vector is not plausible.

Condition

Based on the differential motor model equations the expected voltage vector is calculated from measured motor phase currents and motor speed. This is compared to the output of the field-oriented current controller. In case of large deviations the alert is triggered.

Clear Condition

Ignition off; wait 5 seconds; Ignition on

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+