Alert Details

DPB_a050_supplyUndervoltageLvl3

Description

The voltage supplied to the Decoupled Power Brake (DPB) ECU is below the undervoltage shutdown threshold. Brake system performance is reduced.

Condition

The voltage supplied to the DPB ECU is less than the undervoltage shutdown threshold.

Clear Condition

The issue shall be reset if the supply voltage rises above the undervoltage shutdown level.

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+