Alert Details

DPB_a042_motorLoadPressImplausible

Description

Motor load not plausible to pressure sensor signal.

Condition

The motor load pressure sensor reports an implausible value. This can be caused by the motor not turning due to a blocked gear or high friction or the sensor may be damaged.

Clear Condition

Ignition off; wait 5 seconds; Ignition on

Potential Impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Customer Facing Message 1

Power braking assist reduced

Customer Facing Message 2

Braking may require increased effort

Audiences

customer;service-fix

Models

Model Y 2025+