DPB_a032_HWParamWriteFailed
Description
The Decoupled Power Brake (DPB) parameters in Non-Volatile Memory (NVM) cannot be written.
Condition
Linear Position Sensor IDs NvM write request failed. Alert during write process of NvM Items at ECU Exchange routine.
Clear Condition
Set ECU item 'NvMLipsID' to 4x 0xEE EE and restart System.
Potential Impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Customer Facing Message 1
Power braking assist reduced
Customer Facing Message 2
Braking may require increased effort
Audiences
customer;service-fix
Models
Model Y 2025+