Alert Details

DIRE1R_a244_mechSafeStateApplied

Description

Alert for software trigger of mechanical safe state two-phase disconnect device.

Condition

Software detects a shorted semiconductor switch. The alert log signals provide detailed trigger algorithm info.

Clear Condition

Clears when low voltage (LV) power is removed from drive unit or a non-drive/drive cycle occurs

Potential Impact

The motor is permanently disabled.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Semitruck