MyTeslaMate
DIF family

DIF_a096_memoryError

Not Available

What does the DIF_a096_memoryError alert mean?

The drive interface (DI) or drive inverter (DIx) electronic control unit (ECU) detects a memory check error.

What you'll see in your Tesla

  • Not Available

What triggers it

The bootloader cyclic redundancy check (CRC) or application CRC is not expected, or the RAM constants do not match with initialization segment in flash.

When it clears

Clears automatically 5 seconds after being set.

Potential impact

The DI processor may reset, and other functionality may be impacted due to memory corruption.

Affected models

Cybertruck Model 3 2017-2023 Model 3 2024+ Model S 2021+ Model X 2021+ Model Y Model Y 2025+

Track your Tesla's alerts automatically

Alerts like this reach MyTeslaMate through your car's Tesla telemetry API. MyTeslaMate logs every alert your Tesla reports and turns it into readable history and real-time notifications — hosted TeslaMate with no server to run.