Alert Details

CP_a154_acChargingStoppedOT

Description

The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing AC charging to stop.

Condition

The charge port inlet pin temperature reaches a level where it is unacceptable to continue AC charging (temperature detected greatly exceeds normal operating range).

Clear Condition

The charge cable is disconnected from the charge port inlet. Note: Alert will continue to set until the charge port inlet pin temperature is detected within normal operating range.

Potential Impact

AC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+;Semitruck