Alert Details

CP_a090_ccsEvseLowIso

Description

During a DC fast charging session at a Combined Charging System (CCS) charging station, the electric vehicle supply equipment (EVSE) reports low isolation resistance.

Condition

The CCS DC EVSE reports low isolation resistance during a charging session.

Clear Condition

The CCS DC EVSE reports nominal isolation resistance or the communication channel with the EVSE is no longer established.

Potential Impact

CCS charging may not start or may be interrupted.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+;Semitruck