CP_a034_calibrationIncomplete
Description
Latch calibration data is unavailable.
Condition
EEPROM indicates that the latch offset is not valid for more than 1 second.
Clear Condition
Electrically erasable programmable read-only memory (EEPROM) indicates that the latch offset is valid.
Potential Impact
The CP ECU may not be able to detects the latch position correctly, and the latch may not engage or disengage.
Customer Facing Message 1
Not Available
Customer Facing Message 2
Not Available
Audiences
service-fix
Models
Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+;Semitruck