Alert Details

CC_a006_inputOverCurrent

Description

Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.

Condition

Measured current exceeds configured limit or sharing network allocation by 10 percent + 1 A root mean square (RMS).

Clear Condition

Contactors open for 10 seconds and less than 4 automatic retry attempts, or charge cable cycled.

Potential Impact

Wall connector will stop charging and retry at most 3 times before waiting for the cable to be cycled.

Customer Facing Message 1

Unable to charge - Wall Connector overcurrent

Customer Facing Message 2

Disconnect and retry or use different equipment

Audiences

customer;service

Models

Cybertruck;Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+