Alert Details

BMS_w035_SW_Isolation

Description

There is an external or internal isolation alert while pack contactors are closed.

Condition

The BMS detects that isolation is below the minimum threshold while contactors are closed.

Clear Condition

Isolation restores to the nominal threshold.

Potential Impact

Inability to charge, drive, or support the low voltage (LV) system

Customer Facing Message 1

Vehicle may not restart

Customer Facing Message 2

Service is required

Audiences

customer;service-fix

Models

Model S 2012-2020;Model X 2015-2020