Alert Details

BMS_w033_SW_Crash

Description

The battery management system (BMS) detects that there was loss of power to pack contactors while they are closed. The BMS assumes that the pyro fuse on the contactor power supply signal blew during a crash.

Condition

The BMS detects that there is a loss of power to pack contactors while they are closed.

Clear Condition

The BMS detects that power has been restored to pack contactors.

Potential Impact

Inability to charge, drive, or support the low voltage (LV) system

Customer Facing Message 1

Service is required

Customer Facing Message 2

PULL OVER SAFELY

Audiences

customer

Models

Model S 2012-2020;Model X 2015-2020