Alert Details

BMS_f126_HW_BMS_Blind_Mate

Description

The Complex Programmable Logic Device (CPLD) of the High Voltage (HV) Battery Management System (BMS) detects a blind mate fault bit.

Condition

The CPLD of the HV BMS detects a blind mate fault bit. The HVIL is on and HVIL voltage is greater than the blind mate alert threshold. The CPLD and the BMS concurrently detect the HVIL loop through the HV connector on the battery may not be connected.

Clear Condition

The alert clears when the blind mate is cleared in the CPLD.

Potential Impact

The HV connector on the battery pack is not connected to the HVIL loop. HVIL behavior may be affected.

Customer Facing Message 1

Not Available

Customer Facing Message 2

Not Available

Audiences

service-fix

Models

Model S 2012-2020;Model X 2015-2020