BMS_a050_SW_Brick_Voltage_MIA
Description
The battery management system (BMS) does not have valid data for at least one brick voltage measurement.
Condition
The BMS detects that it does not have valid voltage measurement data for at least one brick.
Clear Condition
The battery management system (BMS) does have valid data for all brick voltage measurements.
Potential Impact
Inability to charge, and power is reduced
Customer Facing Message 1
Unable to charge
Customer Facing Message 2
Service is required
Audiences
customer;service-fix
Models
Model 3 2017-2023;Model 3 2024+;Model S 2021+;Model X 2021+;Model Y;Model Y 2025+